当前位置: X-MOL 学术Theor. Found. Chem. Eng. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Organization of Counter-Mixing of Ozone Flows and Aqueous Solutions
Theoretical Foundations of Chemical Engineering ( IF 0.8 ) Pub Date : 2021-10-25 , DOI: 10.1134/s0040579521040047
A. G. Basiev 1 , A. A. Basiev 1 , A. F. Seliverstov 1 , B. G. Ershov 1
Affiliation  

Abstract

The dissolution of concentrated ozone in water at liquid and gas counter-flows has been studied. It was shown that the ozone flow rate can be increased from 0.042 cm3/s cm2 (flotation treatment of water with ozone) to 3.6 cm3/s cm2 (counter-flow). A scheme of counter-mixing of ozone in gas with water without using flotation technology was suggested. The optimum ratio of ozone carrier gas to water was found to be 1 : 3. The ozone concentration at the reactor outlet was 8 mg/dm3 (4%), and the concentration of ozone dissolved in water reached 45 mg/dm3. A scheme of a unit for counter-mixing of ozone in gas with water was proposed.



中文翻译:

组织臭氧流和水溶液的反向混合

摘要

已经研究了在液体和气体逆流下浓臭氧在水中的溶解。结果表明,臭氧流速可以从 0.042 cm 3 /s cm 2(用臭氧对水进行浮选处理)增加到 3.6 cm 3 /s cm 2(逆流)。提出了一种不使用浮选技术而将气体中的臭氧与水反混合的方案。发现臭氧载气与水的最佳比例为1:3。反应堆出口臭氧浓度为8 mg/dm 3 (4%),臭氧溶解在水中的浓度达到45 mg/dm 3。提出了一种气体中臭氧与水反混合装置的方案。

更新日期:2021-10-26
down
wechat
bug