当前位置: X-MOL 学术ECS J. Solid State Sci. Technol. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Heat Conductivity Based Inner Cavity Pressure Monitoring and Hermeticity Monitoring for Glass Frit Wafer Bonded MEMS Devices
ECS Journal of Solid State Science and Technology ( IF 2.2 ) Pub Date : 2021-08-19 , DOI: 10.1149/2162-8777/ac0e48
Roy Knechtel 1 , Sophia Dempwolf 2 , Siegfried Hering 2
Affiliation  

Hermetic sealing is important regarding functionality and reliability for MEMS components. Typically this sealing is done at the wafer level using wafer bonding, which simultaneously provides mechanical protective caps. Here, a universally usable MEMS Foundry technology for inertial sensors and the glass frit bonding to seal them are introduced. A test structure for inner cavity pressure measurement, utilizing the pressure dependence of heat transfer in gasses, which can be realized in this MEMS technology, is introduced and described for use in detailed investigations of factors, which influence the inner cavity pressure in the wafer pre-processing and wafer bonding step itself. These investigations ultimately allowed optimized wafer processing, improved process control, and reliability investigation. We show how, based on the inner cavity pressure measurements, the glass frit bond process can be set up, that side effects such as storing times of the glass frit can be understood, how fine tuning of the bond process can be done, and how both process stability and device reliability can be efficiently be proven.



中文翻译:

基于热导率的玻璃粉晶圆键合 MEMS 器件的内腔压力监测和气密性监测

气密密封对于 MEMS 组件的功能和可靠性很重要。通常,这种密封是使用晶圆键合在晶圆级完成的,同时提供机械保护帽。在这里,介绍了一种用于惯性传感器的通用 MEMS Foundry 技术和用于密封它们的玻璃料粘合。介绍并描述了一种利用气体传热的压力依赖性进行内腔压力测量的测试结构,该结构可以在该 MEMS 技术中实现,用于详细研究影响晶圆预制件内腔压力的因素。 -处理和晶片键合步骤本身。这些调查最终实现了优化的晶圆加工、改进的过程控制和可靠性调查。我们展示了如何,

更新日期:2021-08-19
down
wechat
bug