当前位置: X-MOL 学术J. Ind. Microbiol. Biotechnol. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Faster, reduced cost calibration method development methods for the analysis of fermentation product using near-infrared spectroscopy (NIRS)
Journal of Industrial Microbiology & Biotechnology ( IF 3.4 ) Pub Date : 2021-06-03 , DOI: 10.1093/jimb/kuab033
Nosa Agbonkonkon 1 , Greg Wojciechowski 1 , Derek A Abbott 1 , Sara P Gaucher 1 , Daniel R Yim 1 , Andrew W Thompson 1 , Michael D Leavell 1
Affiliation  

Recent innovations in synthetic biology, fermentation, and process development have decreased time to market by reducing strain construction cycle time and effort. Faster analytical methods are required to keep pace with these innovations, but current methods of measuring fermentation titers often involve manual intervention and are slow, time-consuming, and difficult to scale. Spectroscopic methods like near-infrared (NIR) spectroscopy address this shortcoming; however, NIR methods require calibration model development that is often costly and time-consuming. Here, we introduce two approaches that speed up calibration model development. First, generalized calibration modeling (GCM) or sibling modeling, which reduces calibration modeling time and cost by up to 50% by reducing the number of samples required. Instead of constructing analyte-specific models, GCM combines a reduced number of spectra from several individual analytes to produce a large pool of spectra for a generalized model predicting all analyte levels. Second, randomized multicomponent multivariate modeling (RMMM) reduces modeling time by mixing multiple analytes into one sample matrix and then taking the spectral measurements. Afterward, individual calibration methods are developed for the various components in the mixture. Time saved from the use of RMMM is proportional to the number of components or analytes in the mixture. When combined, the two methods effectively reduce the associated cost and time for calibration model development by a factor of 10.

中文翻译:

使用近红外光谱 (NIRS) 分析发酵产物的更快、更低成本的校准方法开发方法

合成生物学、发酵和工艺开发方面的最新创新通过减少菌株构建周期时间和工作量来缩短上市时间。需要更快的分析方法来跟上这些创新的步伐,但目前测量发酵滴度的方法通常涉及人工干预,而且速度慢、耗时且难以规模化。近红外 (NIR) 光谱等光谱方法解决了这一缺点。然而,NIR 方法需要开发校准模型,这通常既昂贵又耗时。在这里,我们介绍了两种加快校准模型开发的方法。首先,广义校准建模 (GCM) 或兄弟建模,通过减少所需的样本数量,可将校准建模时间和成本减少多达 50%。GCM 不是构建特定于分析物的模型,而是将来自几个单独分析物的少量光谱组合起来,为预测所有分析物水平的通用模型生成大量光谱。其次,随机多组分多元建模 (RMMM) 通过将多种分析物混合到一个样品基质中然后进行光谱测量来减少建模时间。之后,针对混合物中的各种成分开发单独的校准方法。使用 RMMM 节省的时间与混合物中组分或分析物的数量成正比。结合使用时,这两种方法有效地将校准模型开发的相关成本和时间减少了 10 倍。GCM 将来自几种单独分析物的少量光谱组合在一起,为预测所有分析物水平的通用模型生成大量光谱。其次,随机多组分多元建模 (RMMM) 通过将多种分析物混合到一个样品基质中然后进行光谱测量来减少建模时间。之后,针对混合物中的各种成分开发单独的校准方法。使用 RMMM 节省的时间与混合物中组分或分析物的数量成正比。结合使用时,这两种方法有效地将校准模型开发的相关成本和时间减少了 10 倍。GCM 将来自几种单独分析物的少量光谱组合在一起,为预测所有分析物水平的通用模型生成大量光谱。其次,随机多组分多元建模 (RMMM) 通过将多种分析物混合到一个样品基质中然后进行光谱测量来减少建模时间。之后,针对混合物中的各种成分开发单独的校准方法。使用 RMMM 节省的时间与混合物中组分或分析物的数量成正比。结合使用时,这两种方法有效地将校准模型开发的相关成本和时间减少了 10 倍。随机多组分多元建模 (RMMM) 通过将多种分析物混合到一个样品基质中然后进行光谱测量来减少建模时间。之后,针对混合物中的各种成分开发单独的校准方法。使用 RMMM 节省的时间与混合物中组分或分析物的数量成正比。结合使用时,这两种方法有效地将校准模型开发的相关成本和时间减少了 10 倍。随机多组分多元建模 (RMMM) 通过将多种分析物混合到一个样品基质中然后进行光谱测量来减少建模时间。之后,针对混合物中的各种成分开发单独的校准方法。使用 RMMM 节省的时间与混合物中组分或分析物的数量成正比。结合使用时,这两种方法有效地将校准模型开发的相关成本和时间减少了 10 倍。
更新日期:2021-06-03
down
wechat
bug