The article by Kretschmer et al.1 has been published with incomplete Table 3. Due to a technical error, the last 17 of rows in Table 3 were omitted from the published article. The final results of this article are not impacted by this omission. The correct Table 3 is given below.
The Publisher deeply regrets this error.
Item name | Description | References |
---|---|---|
Code, version, release date | GATE V8.0 released April 20, 2017 and Geant4 10.04.p01 released on February 28, 2018 | Agostinelli et al.15, Jan et al.20 |
Validation | Proton transport: Fano cavity test was passed at a 0.1% level; Electron transport: Agreement with theory within 0.5% | Wulff et al.9; Simiele and DeWerd27 |
Source description | 10 × 10 cm2 parallel beam of monoenergetic protons with incident energies of 70 MeV, 100 MeV, 150 MeV, 200 MeV, and 250 MeV | |
Physics list | QGSP_BIC_EMZ (EMstandardOpt4) | |
Electron transport | ||
MSC model | Goudsmit-Saunderson (E < 100 MeV), WentzelIV (E > 100 MeV) | |
MSC range factor | 0.2 | |
MSC step limitation | fUseSafetyPlus | |
Skin | 3 | |
e–/e+ ionization model | Penelope ionisation (E < 1 MeV), Moller Bhaba (E > 1 MeV) | |
dRoverRange | 0.2 | |
Final range | 10 μm | |
Production cut | 1 μm (scoring volume + 5 mm margin), | |
1 mm (water phantom) | ||
Maximum step size | 1 mm (scoring volume + 5 mm margin) | |
Proton transport | ||
MSC model | WentzelVI Model | |
MSC range factor | 0.2 | |
MSC step limitation | fMinimal | |
Hadron ionization model | Bragg (E < 2 MeV), Bethe-Bloch Formula (E > 2 MeV) | |
dRoverRange | 0.1 | |
Final range | 10 μm | |
Production cut | 1 μm (scoring volume + 5 mm margin), | |
1 mm (water phantom) | ||
Maximum step size | 1 mm (scoring volume + 5 mm margin) | |
Variance reduction techniques | – | |
Scored quantities | Energy deposited in sensitive volume | |
# histories/statistical uncertainty | 200 single batches on a cluster were used with 1E7 and 8E7 primary particles | |
Timing | The equivalent total simulation time for one point on a single CPU corresponds to up to 800 days | |
Statistical methods | batch method | Seco and Verhaegen45 |
Postprocessing | The scored energy deposited from the output files was extracted with MATLAB R2019b46 and divided by the density and volume of the sensitive volume |
中文翻译:
勘误表
Kretschmer 等人的文章。1已发表,表 3 不完整。由于技术错误,已发表文章中省略了表 3 中的最后 17 行。本文的最终结果不受此遗漏的影响。下面给出了正确的表 3。
出版商对这个错误深表遗憾。
项目名称 | 描述 | 参考 |
---|---|---|
代码、版本、发布日期 | 2017年4月20日发布的GATE V8.0和2018年2月28日发布的Geant4 10.04.p01 | 阿戈斯蒂内利等人。15、Jan 等人。20 |
验证 | 质子传输:Fano腔测试在0.1%水平通过;电子传输:与理论的一致性在 0.5% 以内 | 沃尔夫等人。9 ; Simiele 和 DeWerd 27 |
来源描述 | 入射能量为 70 MeV、100 MeV、150 MeV、200 MeV 和 250 MeV 的10 × 10 cm 2平行单能质子束 | |
物理列表 | QGSP_BIC_EMZ (EMstandardOpt4) | |
电子传输 | ||
MSC型号 | Goudsmit-Saunderson (E < 100 MeV), WentzelIV (E > 100 MeV) | |
MSC 范围系数 | 0.2 | |
MSC 步长限制 | fUseSafetyPlus | |
皮肤 | 3 | |
e–/e+ 电离模型 | Penelope 电离 (E < 1 MeV),Moller Bhaba (E > 1 MeV) | |
测距仪 | 0.2 | |
最终范围 | 10微米 | |
减产 | 1 μm(刻痕体积 + 5 mm 余量), | |
1毫米(水幻影) | ||
最大步长 | 1 毫米(评分量 + 5 毫米余量) | |
质子运输 | ||
MSC型号 | WentzelVI 模型 | |
MSC 范围系数 | 0.2 | |
MSC 步长限制 | 最小 | |
强子电离模型 | 布拉格(E < 2 MeV),Bethe-Bloch 公式(E > 2 MeV) | |
测距仪 | 0.1 | |
最终范围 | 10微米 | |
减产 | 1 μm(刻痕体积 + 5 mm 余量), | |
1毫米(水幻影) | ||
最大步长 | 1 毫米(评分量 + 5 毫米余量) | |
方差减少技术 | —— | |
计分数量 | 能量沉积在敏感体积 | |
# 历史/统计不确定性 | 使用 1E7 和 8E7 初级粒子在一个簇上使用 200 个单批次 | |
定时 | 单个 CPU 上一个点的等效总仿真时间对应最多 800 天 | |
统计方法 | 批处理方法 | 山高和 Verhaegen 45 |
后期处理 | 使用 MATLAB R2019b 46提取从输出文件中存储的评分能量,并除以敏感体积的密度和体积 |