Variation in sag values in daily disposable, reusable and toric soft contact lenses
Contact Lens & Anterior Eye ( IF 3.2 ) Pub Date : 2021-01-08 , DOI: 10.1016/j.clae.2020.11.006
Eef van der Worp 1 , Matthew Lampa 2 , Beth Kinoshita 2 , Mari J Fujimoto 2 , Benjamin J Coldrick 3 , Patrick Caroline 2
Affiliation  

Purpose

While knowledge of the ocular surface sagittal height (OC-SAG) is increasing with newer instrumentation, understanding of soft lens sag values (CL-SAG) in daily clinical practice is limited. This study aimed to report the differences in CL-SAG of a large collection of daily disposable (DD), reusable (2-week and 4-week replacement) and toric lens designs.

Methods

12 different spherical DD and 15 reusable lens types were analysed (labelled power −3.00D); 17 different toric lens types analysed (6 DD and 11 reusable) in −3.00D =C 0.75 × 180. Posterior CL-SAG was measured directly using a spectral domain OCT-based instrument (Optimec is830).

Results

The range in CL-SAG for DDs was 3,398-3,912 microns, for reusable lenses 3,372-4,004 microns and for toric lenses 3,536-4,157 microns. Lens diameter and BC together influence CL-SAG values. For lenses with the same labelled base curve (BC), the maximum difference in the DD group was 264 microns, in the reusable group 418 microns and in the toric group 345 microns. Three lens designs within the DD group and five in the reusable group offer two BCs, with an average variation (±SD) in CL-SAG of 276 ± 39 microns; one toric lens with two BCs showed a 377-micron difference.

Conclusions

Marked differences in CL-SAG values were found in this study, also between lenses of the same BC. While ECPs should be aware that diameter and BC together influence CL-SAG, this also indicates that lens substitution based on BC alone could result in substantial differences in CL-SAG, with a potential impact on lens fit. Lens designs offering two BCs showed a somewhat narrow band in absolute terms in CL-SAG, and switching from a spherical to a toric lens of the same lens manufacturer could result in a significant change in CL-SAG.



中文翻译:

日抛型、可重复使用型和复曲面软性隐形眼镜下垂值的变化

目的

虽然随着仪器的更新,对眼表矢状高度 (OC-SAG) 的了解越来越多,但在日常临床实践中对软晶状体下垂值 (CL-SAG) 的了解却很有限。本研究旨在报告大量日抛型 (DD)、可重复使用(2 周和 4 周更换)和复曲面镜片设计的 CL-SAG 差异。

方法

分析了 12 种不同的球面 DD 和 15 种可重复使用的镜片类型(标记为 -3.00D);在 -3.00D =C 0.75 × 180 中分析了 17 种不同的复曲面镜片类型(6 种 DD 和 11 种可重复使用)。使用基于光谱域 OCT 的仪器(Optimec is830)直接测量后部 CL-SAG。

结果

DD 的 CL-SAG 范围为 3,398-3,912 微米,可重复使用镜片为 3,372-4,004 微米,复曲面镜片为 3,536-4,157 微米。镜片直径和 BC 共同影响 CL-SAG 值。对于具有相同标记基弧 (BC) 的镜片,DD 组的最大差异为 264 微米,可重复使用组为 418 微米,复曲面组为 345 微米。DD 组中的三个镜片设计和可重复使用组中的五个镜片设计提供两个 BC,CL-SAG 的平均变化 (±SD) 为 276 ± 39 微米;一个带有两个 BC 的复曲面镜片显示出 377 微米的差异。

结论

在这项研究中发现了 CL-SAG 值的显着差异,在相同 BC 的镜片之间也是如此。虽然 ECP 应该意识到直径和 BC 共同影响 CL-SAG,但这也表明仅基于 BC 的镜片替换可能会导致 CL-SAG 的显着差异,并可能影响镜片适合度。提供两个 BC 的镜头设计在 CL-SAG 的绝对值上显示出较窄的带,从球面镜片切换到同一镜片制造商的复曲面镜片可能会导致 CL-SAG 发生显着变化。