当前位置: X-MOL 学术Appl. Acoust. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Precision of ISO 3382-2 and ISO 3382-3 – A Round-Robin test in an open-plan office
Applied Acoustics ( IF 3.4 ) Pub Date : 2020-12-24 , DOI: 10.1016/j.apacoust.2020.107846
Valtteri Hongisto , Jukka Keränen , Laura Labia , Reijo Alakoivu

International standards ISO 3382-2 and ISO 3382-3 are increasingly applied to determine the room acoustic conditions in open-plan offices because attention to noise control in such workplaces has increased. The precision of those standards in open-plan offices has not been published. The purpose of this study was to determine the precision of ISO 3382-2:2008 and ISO 3382-3:2012 in an open-plan office following the instructions of ISO 5725 standard. Furthermore, the results were analyzed in the light of ISO CD 3382-3:2020 involving improvements related to uncertainty. An accuracy experiment (a.k.a Round-Robin test, inter-laboratory test, intercomparison test) was arranged where nine independent participants conducted the measurements in the same open-plan office. For ISO 3382-3:2012, the reproducibility standard deviations were 530.5 dB, 1.3 dB, 1.3 dB, and 18% for spatial decay rate of speech (D2,S), A-weighted SPL of speech at 4 m distance (Lp,A,S,4m), A-weighted SPL of background noise (Lp,A,B), and distraction distance (rD). The corresponding values for ISO CD 3382-3:2020 were 0.3 dB, 1.1 dB, 0.6 dB, and 16%, respectively. The reproducibility standard deviations for reverberation time were 4.5–16% within 1/1-octave bands 125–8000 Hz. The measurement uncertainty of ISO CD 3382-3:2020 is smaller than that of ISO 3382-3:2012. The values depended mainly on between-laboratory differences while within-laboratory differences had only a marginal impact. The results can be used in the development of the standards.



中文翻译:

ISO 3382-2和ISO 3382-3的精度–在开放式办公室中进行的循环测试

国际标准ISO 3382-2和ISO 3382-3越来越多地用于确定开放式办公室的室内声学条件,因为这种工作场所对噪声控制的关注日益增加。这些标准在开放式办公室中的准确性尚未公布。这项研究的目的是按照ISO 5725标准的说明,在开放式办公室中确定ISO 3382-2:2008和ISO 3382-3:2012的精度。此外,根据ISO CD 3382-3:2020分析了结果,涉及不确定性方面的改进。安排了一个准确性实验(又名轮循测试,实验室间测试,比对测试),其中有9名独立参与者在同一开放式办公室中进行了测量。对于ISO 3382-3:2012,可再现性标准偏差为530.5 dB,1.3 dB,1。D 2,S),4 m距离处的A加权语音声L p,A,S,4m),背景噪声的A加权SPLL p,A,B)和干扰距离(r D) 。ISO CD 3382-3:2020的相应值分别为0.3 dB,1.1 dB,0.6 dB和16%。在125-8000 Hz的1/1倍频程内,混响时间的再现性标准偏差为4.5-16%。ISO CD 3382-3:2020的测量不确定度小于ISO 3382-3:2012的测量不确定度。这些值主要取决于实验室之间的差异,而实验室内部的差异仅具有很小的影响。结果可用于标准的制定。

更新日期:2020-12-24
down