当前位置: X-MOL 学术Electroanalysis › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Bimetallic CuCo Derived from Prussian Blue Analogue for Nonenzymatic Glucose Sensing
Electroanalysis ( IF 3 ) Pub Date : 2020-11-02 , DOI: 10.1002/elan.202060402
Gang Ni 1 , Feifan Wang 1 , Zhiqiu Pan 1 , Ruihan Zhang 1
Affiliation  

Bimetallic CuCo composites are prepared by calcinating copper hexacyanocobaltate precursor in N2 atmosphere. The CuCo modified electrodes are fabricated for nonenzymatic glucose sensing in the alkaline electrolyte. The glucose can be directly electro‐oxidized on the surface of the electrode catalyst mediated by the redox couples of Cu and Co. The optimal glucose sensor exhibits a high sensitivity (567 μA ⋅ mM−1 ⋅ cm−2) in the range up to 825 μM with a detection limit of 3 μM and acceptable selectivity. The sensor can also be applied in serum samples. This work provides a facile and easily‐scalable synthesis method of electrocatalysts for nonenzymatic glucose sensors.

中文翻译:

普鲁士蓝类似物衍生的双金属CuCo用于非酶葡萄糖感测

通过在N 2气氛中煅烧六氰基钴酸铜前驱体来制备双金属CuCo复合材料。CuCo修饰电极可用于碱性电解质中的非酶葡萄糖传感。葡萄糖可以被直接电氧化的Cu和Co.的氧化还原对介导的电极催化剂的表面上最佳葡萄糖传感器具有高的灵敏度(567μA⋅毫-1  ⋅厘米-2)的范围内可达825μM,检测限为3μM,选择性可接受。该传感器还可以应用于血清样品中。这项工作为非酶葡萄糖传感器提供了一种简便,易于扩展的电催化剂合成方法。
更新日期:2020-11-02
down
wechat
bug