FARICH detector beam test results
Journal of Instrumentation ( IF 1.3 ) Pub Date : 2020-10-08 , DOI: 10.1088/1748-0221/15/10/c10014
A.Yu. Barnyakov 1, 2, 3 , M.Yu. Barnyakov 1 , V.S. Boborovnikov 1, 2 , A.R. Buzykaev 1, 2 , A.V. Bykov 1 , A.F. Danilyuk 2, 4 , P.V. Kasyanenko 1, 2 , A.A. Katcin 1, 2 , S.A. Kononov 1, 2 , E.A. Kravchenko 1, 2 , I.A. Kuyanov 1, 2 , A.P. Onuchin 1, 2 , I.V. Ovtin 1, 2 , N.A. Podgornov 1, 2 , V.V. Porosev 1, 2 , A.S. Shalygin 4 , L.I. Shekhtman 1, 2 , A.A. Talyshev 1, 2
Affiliation  

The excellent particle identification (PID) system is needed for the successful execution of the broad experimental program at future Super C-τ Factory (SCTF) in Novosibirsk. The main requirements for the PID system are the following: good π/K-separation in whole operational momentum range and good μ/π-separation in the momentum range from 0.4 up to 1.2 GeV/ c . The RICH detector based on focusing aerogel (FARICH) could provide good π/K-separation from 0.4 GeV/ c and μ/π-separation in the momentum range from 0.4 up to 1.5 GeV/ c . The method FARICH is described, beam test results are presented and the status of multilayer aerogel production is given.

中文翻译:

FARICH探测器光束测试结果

要在新西伯利亚的未来超级C-τ工厂(SCTF)成功执行广泛的实验程序,需要出色的颗粒识别(PID)系统。PID系统的主要要求如下:在整个运行动量范围内良好的π/ K分离和在0.4至1.2 GeV / c的动量范围内良好的μ/π分离。基于聚焦气凝胶的RICH检测器(FARICH)在0.4 GeV / c的动量范围内可以提供良好的π/ K分离(从0.4 GeV / c分离)和μ/π分离。描述了FARICH方法,给出了束测试结果,并给出了多层气凝胶生产的状态。