SINIS Bolometer with Microwave Readout
Physics of the Solid State ( IF 0.6 ) Pub Date : 2020-09-09 , DOI: 10.1134/s1063783420090292 M. A. Tarasov , S. Mahashabde , A. A. Gunbina , R. A. Yusupov , A. M. Chekushkin , S. A. Lemzyakov , D. V. Nagirnaya , M. A. Mansfel’d , V. F. Vdovin , V. S. Edel’man , A. S. Kalaboukhov , D. Winkler
中文翻译:
SINIS微波读数计,带微波读数
更新日期:2020-09-09
Physics of the Solid State ( IF 0.6 ) Pub Date : 2020-09-09 , DOI: 10.1134/s1063783420090292 M. A. Tarasov , S. Mahashabde , A. A. Gunbina , R. A. Yusupov , A. M. Chekushkin , S. A. Lemzyakov , D. V. Nagirnaya , M. A. Mansfel’d , V. F. Vdovin , V. S. Edel’man , A. S. Kalaboukhov , D. Winkler
Abstract
A bolometer, which is based on a superconductor–insulator–normal metal–insulator–superconductor (SINIS) structure, integrated into a twin-slot antenna with a central frequency of 90 GHz, and connected with a superconducting microwave readout resonator, has been designed, fabricated, and experimentally studied. Such an elementary cell is designed for the multi-element array of a high-sensitive radioastronomic receiver, in which the readout from a great number of channels is performed by a single coaxial cable instead of separate wires and amplifier in each channel.中文翻译: