当前位置: X-MOL 学术Am. J. Physiol. Regul. Integr. Comp. Physiol. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Evaluating the suitability of supra-POpeak verification trials after ramp-incremental exercise to confirm the attainment of maximum O2 uptake.
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology ( IF 2.8 ) Pub Date : 2020-07-22 , DOI: 10.1152/ajpregu.00126.2020
Danilo Iannetta 1 , Rafael de Almeida Azevedo 1 , Christina P Ingram 1 , Daniel A Keir 2 , Juan M Murias 1
Affiliation  

During exhaustive ramp-incremental cycling tests, the incidence of O2 uptake (V̇O2) plateaus is low. To verify the attainment of maximum V̇O2 (V̇O2max), it is recommended that a trial at a power output (PO) corresponding to 110% of the ramp-derived peak (POpeak) is performed. It remains unclear whether verification trials set at this PO can be tolerated for long enough to allow attainment of V̇O2max. Eleven recreationally-trained individuals performed five ramp tests of varying slope (5, 10, 15, 25, 30 W·min-1), each followed, in series, by two verification trials: the 1st at 110%POpeak of the 25 W·min-1 ramp and the 2nd at 110% POpeak attained in the preceding ramp test. Exercise duration of the 1st verification trial was on average 81±15 s (CV=9±3%) versus 162±32, 121±24, 103±15, and 73±10 s for the 2nd verification trials at 110% of POpeak of the 5, 10, 15, and 30 W·min-1 ramp tests, respectively (P<0.05). Compared to the highest V̇O2 recorded during ramp tests, V̇O2 from the subsequent verification trials were not different for the 5, 10, and 15 W·min-1 ramp tests (P>0.05), but lower for the 25 and 30 W·min-1 ramp tests (P<0.05). Verification trials at 110%POpeak of rapidly-incrementing ramp tests (i.e., 25 W·min-1) were not sustained for long enough to allow the attainment of V̇O2max. With commonly used rapidly-incrementing ramp tests engendering exhaustion within 8-12 min, verification trials <POpeak should be preferred as they can be sustained sufficiently long to allow the attainment of V̇O2max.

中文翻译:

在斜坡增量练习后评估 supra-POpeak 验证试验的适用性,以确认达到最大 O2 吸收。

在详尽的斜坡增量循环测试中,O 2吸收 (V̇O 2 ) 平台的发生率很低。为了验证是否达到最大 V̇O 2 (V̇O 2max ),建议在对应于斜坡衍生峰值(PO peak ) 110% 的功率输出 (PO) 下进行试验。尚不清楚在此 PO 上设置的验证试验是否可以容忍足够长的时间以允许达到 V̇O 2max。十一娱乐性训练的个体进行变化的坡度的斜坡5个测试(5,10,15,25,30瓦·分钟-1)由两个验证试验中,每个随后,串联:1110%PO的25瓦·分钟-1斜坡和2在110%PO前述斜坡测试实现。第一次验证试验的运动持续时间平均为 81±15 秒(CV=9±3%),而第二次验证试验的平均持续时间为162±32、121±24、103±15 和 73±10 秒(110%)分别在 5、10、15和 30 W·min -1斜坡试验中的 PO峰值(P<0.05)。与斜坡测试期间记录的最高 V̇O 2相比,来自后续验证试验的V̇O 2在 5、10 和 15 W·min -1斜坡测试中没有差异(P>0.05),但在 25 和 30 W 时较低·min -1斜坡测试(P<0.05)。110%PO 时的验证试验快速增加斜坡测试的峰值(即,25 W·min -1)没有持续足够长的时间以允许达到 V̇O 2max。由于常用的快速递增斜坡测试会在 8-12 分钟内产生疲劳,因此应首选验证试验 <PO峰值,因为它们可以持续足够长的时间以达到 V̇O 2max
更新日期:2020-08-20