当前位置: X-MOL 学术IEEE Microw. Wirel. Compon. Lett. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Polarization Detection of Electromagnetic Waves Using Cascaded Wilkinson Power Dividers
IEEE Microwave and Wireless Components Letters ( IF 3 ) Pub Date : 2020-08-01 , DOI: 10.1109/lmwc.2020.3005285
Gustavo G. S. Forte , Glauco Fontgalland , Hugerles S. Silva

This letter presents a new technique for determining the polarization of the electromagnetic waves by using a passive circuit. The necessary mathematical operations required to retrieve the polarization are achieved using a passive circuit built with the cascaded Wilkinson power dividers. This technique is robust and simple, and enables the detection of all necessary characteristics for determining the incident-wave polarization. It requires two orthogonal linearly polarized antennas for amplitude measurements only. Measurement results with two circularly polarized patch antennas are shown in order to validate the proposed technique. A comparison with a classic method is also provided, which confirms the accuracy and simplicity of the technique.

中文翻译:

使用级联威尔金森功率分配器的电磁波极化检测

这封信提出了一种通过使用无源电路来确定电磁波极化的新技术。使用由级联威尔金森功率分配器构建的无源电路来实现恢复极化所需的必要数学运算。该技术稳健且简单,并且能够检测确定入射波偏振所需的所有特征。它只需要两个正交线性极化天线用于幅度测量。显示了两个圆极化贴片天线的测量结果,以验证所提出的技术。还提供了与经典方法的比较,证实了该技术的准确性和简单性。
更新日期:2020-08-01
down
wechat
bug