Performance analysis of bismuth-antimony-telluride-selenium alloy-based trapezoidal-shaped thermoelectric pallet for a cooling application
Energy Conversion and Management ( IF 8.208 ) Pub Date : 2020-07-30 , DOI: 10.1016/j.enconman.2020.113245
Abu Raihan Mohammad Siddique; Kumar Venkateshwar; Shohel Mahmud; Bill Van Heyst

The zero emission and chlorofluorocarbons (CFC) free thermoelectric cooling systems have the potential to limit the adverse effect on our climate due to the greenhouse gas emission from traditional cooling technologies. In this paper, a new configuration of thermoelectric cooling system is proposed, which includes trapezoidal-shaped solid-state thermoelectric legs, bismuth-antimony-telluride-selenium alloy, and it is manufactured using environmentally friendly handheld dispenser fabrication method. The synthesized thermoelectric materials are characterized using x-ray powder diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscope (SEM) technologies in order to study the morphology of the materials. Both theoretical and experimental studies are performed on trapezoidal and rectangular prototypes. It is identified that the trapezoidal-shaped leg requires less material (nearly 25% less) and exhibits lower thermal conductance (around 27% less) in comparison with the rectangular-shaped TE leg. Experimental results further show that a maximum temperature difference of 79.4 °C can be achieved from the trapezoidal-shaped prototype at 5A input current which is 10% higher than the rectangular prototype. Besides, an experimentally validated analytical model is used to investigate further the cooling capability, temperature difference, and coefficient of performance of both trapezoidal and rectangular-shaped TEC. A range of area ratio of the hot surface to the cold surface of the TE leg varying from 0.33 to 3 has been studied. In addition, the maximum COP of the trapezoidal-shaped prototype is approximately 32.5% higher than the rectangular prototype. The maximum obtainable cooling rate and temperature difference are almost the same but require nearly 50% less input current to achieve this maximum output with a hot to cold surface area ratio of 0.33.

更新日期:2020-07-31

 

全部期刊列表>>
施普林格自然
欢迎访问IOP中国网站
GIANT
自然职场线上招聘会
ACS ES&T Engineering
ACS ES&T Water
屿渡论文,编辑服务
何川
苏昭铭
陈刚
姜涛
李闯创
复旦大学
刘立明
隐藏1h前已浏览文章
课题组网站
新版X-MOL期刊搜索和高级搜索功能介绍
ACS材料视界
天合科研
x-mol收录
上海纽约大学
曾林
天津大学
何振宇
史大永
吉林大学
卓春祥
张昊
刘冬生
试剂库存
down
wechat
bug