Effect of oscillation frequency on the breakdown characteristics of transformer oil in a highly nonuniform field under lightning impulse voltage
IEEE Transactions on Dielectrics and Electrical Insulation ( IF 3.1 ) Pub Date : 2020-06-01 , DOI: 10.1109/tdei.2020.008636
Su Zhao , Ruishuang Zhong , Dengming Xiao , Yunkun Deng

This study presents the influence of the waveform oscillation frequency on the breakdown of transformer oil in a highly nonuniform field under the lightning impulse voltage waveform. Four oscillating frequency waveforms, as per IEC 60060-3 standard, are applied and the standard lightning impulse (SLI) waveform is adopted as the test reference waveform. The experimental results show that breakdown under the oscillating lightning impulse (OLI) always occurs at the peak of the oscillation cycle, the voltage then rapidly decays to zero, followed by a small recovery with oscillation occurs when upon a breakdown. The breakdown voltages under the OLI waveforms are higher than those under the SLI waveform. Moreover, breakdown voltage rises with the increasing oscillating frequency. The analysis of breakdown distribution points and voltage time characteristics curves show that discharge time lag for OLI is longer than that for SLI and tends to decrease as the frequency increases. Weibull breakdown probability curves show that agglomeration occurs when the voltage reaches a high value. The breakdown mechanism is analyzed and the statistical time lags under different impulse voltages are compared. The results of this study can provide an important support for the field lightning impulse test of oil-immersed power transformers.

中文翻译:

雷电冲击电压下振荡频率对高度不均匀场变压器油击穿特性的影响

本研究介绍了在雷电冲击电压波形下,波形振荡频率对高度不均匀场中变压器油击穿的影响。应用符合 IEC 60060-3 标准的四种振荡频率波形,并采用标准雷电脉冲 (SLI) 波形作为测试参考波形。实验结果表明,振荡雷电脉冲(OLI)下的击穿总是发生在振荡周期的峰值,然后电压迅速衰减到零,然后在击穿时出现小幅恢复振荡。OLI 波形下的击穿电压高于 SLI 波形下的击穿电压。此外,击穿电压随着振荡频率的增加而升高。对击穿分布点和电压时间特性曲线的分析表明,OLI的放电时滞比SLI的长,并且随着频率的增加而减小。Weibull 击穿概率曲线表明,当电压达到高值时会发生团聚。分析了击穿机理,比较了不同冲击电压下的统计时滞。该研究结果可为油浸式电力变压器现场雷电冲击试验提供重要支持。分析了击穿机理,比较了不同冲击电压下的统计时滞。该研究结果可为油浸式电力变压器现场雷电冲击试验提供重要支持。分析了击穿机理,比较了不同冲击电压下的统计时滞。该研究结果可为油浸式电力变压器现场雷电冲击试验提供重要支持。
更新日期:2020-06-01
down
wechat
bug