当前位置: X-MOL 学术J. Engin. Thermophys. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Effect of Nozzle Geometry on Particle Size Distribution in Atomized Spray of Metastable Superheated Liquid
Journal of Engineering Thermophysics ( IF 2.4 ) Pub Date : 2019-12-09 , DOI: 10.1134/s1810232819040088
Yu. A. Zeigarnik , V. I. Zalkind , L. V. Nizovskii , V. L. Nizovskii , S. S. Shchigel

It is experimentally shown that diverging nozzles with a cone angle of 12o -14° and a length of 10-15 mm provide the finest atomization of metastable superheated liquid with a submicron droplet fraction at a level of 65-70%.

中文翻译:

喷嘴几何形状对亚稳态过热液体雾化喷雾中粒径分布的影响

实验表明,锥角为12 o -14°且长度为10-15 mm的发散喷嘴可提供亚微米级液滴百分比为65-70%的亚稳态过热液体的最佳雾化。