Tension force analysis of geotextile tubes by half cross-section test
Geotextiles and Geomembranes ( IF 5.2 ) Pub Date : 2020-06-01 , DOI: 10.1016/j.geotexmem.2019.11.004
H.J. Kim , P.R. Dinoy , H.S. Kim

Abstract A simplified equation, which allows for the calculation of the tension force using the actual tube height and pumping pressure with the flexibility to use a coefficient of lateral pressure (K), is proposed and validated theoretically by comparing the proposed method with two well-known methods in the literature, and experimentally, by conducting several half cross-section tests. The half cross-section test proposed in this study is unique and configured in such a way that the top and bottom of the geotextile tube is supported by load cells to be able to quantitatively measure the maximum tension force, as well as the stress and strain of the geotextile tube. With the use of the simplified equation, the actual field conditions can be exceptionally represented, making it more advantageous over the previous methods.