当前位置: X-MOL 学术Int. J. Fatigue › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
On specimen design for high cycle fatigue testing of welded joint
International Journal of Fatigue ( IF 6 ) Pub Date : 2020-07-01 , DOI: 10.1016/j.ijfatigue.2020.105597
Shi-Chen Li , Wei-Chang Zhang , Ming-Liang Zhu , Fu-Zhen Xuan

Abstract Axially push-pull fatigue tests of a low-strength Cr-Ni-Mo-V steel welded joint using cross-weld specimens with two types of sampling, i.e., weld metal centered and heat-affected zone centered, were conducted up to 5 × 107 cycles at room temperature and 300 °C. Fatigue strength of heat-affected zone centered specimen was higher due to dynamic strain aging at weld metal at 300 °C and a locally mismatched deformation around heat-affected zone. The failure location varied as a result of mismatched deformation, structural soft zone, and micro-defects. The sampling dependence implied for a proper fatigue design and assessment of welded structures.

中文翻译:

焊接接头高周疲劳试验试件设计

摘要 采用交叉焊缝试样对低强度 Cr-Ni-Mo-V 钢焊接接头进行轴向推拉疲劳试验,采用焊缝金属居中和热影响区居中两种取样方式进行了长达 5 次的轴向推拉疲劳试验。 × 在室温和 300 °C 下循环 107 次。由于焊缝金属在 300 °C 的动态应变时效和热影响区周围的局部不匹配变形,热影响区中心试样的疲劳强度更高。由于不匹配的变形、结构软区和微缺陷,破坏位置会发生变化。采样相关性意味着适当的疲劳设计和焊接结构的评估。
更新日期:2020-07-01
down
wechat
bug