The current study compared optical quality before and after implantation of a posterior chamber phakic intraocular lens with a central hole [V4c implantable collamer lens (ICL)] under bright and dark lighting conditions by means of the Optical Quality Analysis System™ (OQAS; Visiometrics, Terrassa, Spain). This prospective study involved 91 eyes of 46 consecutive high myopia patients (15 males and 31 females, average spherical equivalent − 10.50 ± 0.33D) undergoing implantation of a V4c ICL. The modulation transfer function (MTF) cutoff frequency, Strehl ratio, objective scattering index (OSI), and predicted visual acuities (PVAs; 100, 20, and 9%), under different lighting conditions, were measured before and 1 week, 1 month, and 3 months after surgery. All optical parameters showed significant improvements, at all time points, under dark condition after surgery. We observed no significant changes in PVA 9% at 1 week (mean value 0.539, P = 0.12) or 1 month after surgery (mean value 0.573, P = 0.08) under bright condition; but all other postoperative parameters improved significantly. Comparing the two lighting conditions, the OSI decreased more under dark conditions at 1 week (P = 0.02), 1 month (P = 0.004), and 3 months (P = 0.002), but there was no significant difference in any other parameter. In addition, patients were divided into super high myopia (group S, spherical equivalent greater than − 10 D) and high myopia (group H, spherical equivalent from − 6 D to − 10 D), the group S improved significantly more than group H in all parameters, under both bright and dark conditions. V4c ICL implantation improved optical quality under both bright and dark lighting conditions, and had a better ability to reduce the extent of scattering in the dark. Furthermore, group S achieved greater improvement in visual quality, which should be considered by physicians before surgery.

中文翻译:

在不同照明条件下后房角膜植入有中心孔的人工晶状体(V4c植入式Collamer晶状体)后的光学质量

当前的研究通过光学质量分析系统(OQAS; Visiometrics)比较了在明亮和黑暗的照明条件下,在有中央孔的后房有晶状体人工晶状体植入前后的光学质量[V4c可植入的聚光透镜(ICL)]西班牙Terrassa)。这项前瞻性研究涉及接受V4c ICL植入的46例连续高度近视患者(男性15例,女性31例,平均球当量-10.50±0.33D)的91眼。在不同的光照条件下,在1周,1个月之前和1周内测量了调制传递函数(MTF)的截止频率,斯特列尔比,客观散射指数(OSI)和预测的视敏度(PVA; 100%,20%和9%) ,以及术后3个月。在所有时间点,所有光学参数均显示出显着改善,手术后在黑暗条件下。在明亮的条件下,术后1周(平均值0.539,P = 0.12)或术后1个月(平均值0.573,P = 0.08),PVA 9%均无明显变化;但所有其他术后参数均明显改善。比较这两种光照条件,在黑暗条件下1周(P = 0.02),1个月(P = 0.004)和3个月(P = 0.002)时,OSI下降更多,但其他任何参数均无显着差异。此外,将患者分为超高度近视(S组,球体当量大于-10 D)和高度近视(H组,球体当量从-6 D到-10 D),S组比H组有明显改善在所有参数下,无论是在明暗条件下。V4c ICL植入改善了在明亮和黑暗照明条件下的光学质量,并具有减少黑暗中散射程度的更好能力。此外,S组在视觉质量上有更大的改善,医师应在手术前予以考虑。
更新日期:2020-03-04
down
wechat
bug