当前位置: X-MOL 学术Bioelectromagnetics › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Design and Dosimetric Analysis of an Exposure Facility for Investigating Possible Effects of 2.45 GHz Wi-Fi Signals on Human Sleep.
Bioelectromagnetics ( IF 1.9 ) Pub Date : 2020-02-27 , DOI: 10.1002/bem.22256
Gernot Schmid 1 , Rene Hirtl 1 , Ana Bueno-Lopez 2 , Hans Dorn 2 , Torsten Eggert 2 , Heidi Danker-Hopfe 2
Affiliation  

A new head exposure system for double-blind provocation studies investigating possible effects of 2.45 GHz Wi-Fi exposure on human sleep was developed and dosimetrically analyzed. The exposure system includes six simultaneously radiating directional antennas arranged along a circle (radius 0.6 m) around the test subject's head, and enables a virtually uniform head exposure, i.e. without any preferred direction of incidence, during sleep. The system is fully computer-controlled and applies a real wireless local area network (WLAN) signal representing different transmission patterns as expected in real WLAN scenarios, i.e. phases of "beacon only" as well as phases of different data transmission rates. Sham and verum are applied in a double-blind crossover study design and all relevant exposure data, i.e. forward and reverse power at all six antenna inputs, are continuously recorded for quality control. For a total antenna input power (sum of all antennas) of 220 mW, typical specific absorption rate (SAR) in cortical brain regions is approximately 1-2 mW/kg (mass average SAR over respective brain region), which can be seen as a realistic worst-case exposure level in real WLAN scenarios. Taking into account variations of head positions during the experiments, the resulting exposure of different brain regions may deviate from the given average SAR levels up to 10 dB. Peak spatial 10 g average SAR in all brain and all head tissues is between 1.5-3.5 and 10.4-25 mW/kg, respectively. Bioelectromagnetics. © 2020 Bioelectromagnetics Society.

中文翻译:

用于研究2.45 GHz Wi-Fi信号可能对人体睡眠造成影响的曝光设备的设计和剂量分析。

开发了一种用于双盲激发研究的新型头部暴露系统,该系统研究了2.45 GHz Wi-Fi暴露对人类睡眠的可能影响,并进行了剂量分析。曝光系统包括六个同时辐射的定向天线,这些天线沿着被测者的头部周围的一个圆(半径为0.6 m)布置,并在睡眠期间实现几乎均匀的头部暴露,即没有任何优选的入射方向。该系统完全由计算机控制,并施加一个真实的无线局域网(WLAN)信号,该信号代表实际WLAN场景中预期的不同传输模式,即“仅信标”阶段以及不同数据传输速率的阶段。在双盲交叉研究设计和所有相关的暴露数据中均应用了假手术和Verum。连续记录所有六个天线输入的正向和反向功率,以进行质量控制。对于220 mW的总天线输入功率(所有天线之和),皮层大脑区域的典型比吸收率(SAR)约为1-2 mW / kg(各个大脑区域的质量平均SAR),可以看作是实际WLAN场景中的实际最坏情况暴露水平。考虑到实验过程中头部位置的变化,不同大脑区域的暴露结果可能会偏离给定的平均SAR电平,最高可达10 dB。所有大脑和所有头部组织的峰值空间10 g平均SAR分别在1.5-3.5和10.4-25 mW / kg之间。生物电磁学。©2020生物电磁学会。对于220 mW的总天线输入功率(所有天线之和),皮层大脑区域的典型比吸收率(SAR)约为1-2 mW / kg(各个大脑区域的质量平均SAR),可以看作是实际WLAN场景中的实际最坏情况暴露水平。考虑到实验过程中头部位置的变化,不同大脑区域的暴露结果可能会偏离给定的平均SAR电平,最高可达10 dB。所有大脑和所有头部组织的峰值空间10 g平均SAR分别在1.5-3.5和10.4-25 mW / kg之间。生物电磁学。©2020生物电磁学会。对于220 mW的总天线输入功率(所有天线之和),皮层大脑区域的典型比吸收率(SAR)约为1-2 mW / kg(各个大脑区域的质量平均SAR),可以看作是实际WLAN场景中的实际最坏情况暴露水平。考虑到实验过程中头部位置的变化,不同大脑区域的暴露结果可能会偏离给定的平均SAR电平,最高可达10 dB。所有大脑和所有头部组织的峰值空间10 g平均SAR分别在1.5-3.5和10.4-25 mW / kg之间。生物电磁学。©2020生物电磁学会。在实际的WLAN场景中,这可以看作是现实的最坏情况下的暴露水平。考虑到实验过程中头部位置的变化,不同大脑区域的暴露结果可能会偏离给定的平均SAR电平,最高可达10 dB。所有大脑和所有头部组织的峰值空间10 g平均SAR分别在1.5-3.5和10.4-25 mW / kg之间。生物电磁学。©2020生物电磁学会。在实际的WLAN场景中,这可以看作是现实的最坏情况下的暴露水平。考虑到实验过程中头部位置的变化,不同大脑区域的暴露结果可能会偏离给定的平均SAR电平,最高可达10 dB。所有大脑和所有头部组织的峰值空间10 g平均SAR分别在1.5-3.5和10.4-25 mW / kg之间。生物电磁学。©2020生物电磁学会。
更新日期:2020-03-16
down
wechat
bug