当前位置: X-MOL 学术BMC Gastroenterol. › 论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
Evaluation of ultrasound-guided Freka-Trelumina enteral nutrition tube placement in the treatment of acute pancreatitis.
BMC Gastroenterology ( IF 2.4 ) Pub Date : 2020-01-29 , DOI: 10.1186/s12876-020-1172-0
Zhijun Liu 1 , Jintao Guo 2 , Weidong Ren 1 , Shaoshan Tang 1 , Ying Huang 1 , Liping Huang 1 , Siyu Sun 2 , Lianjie Lin 3
Affiliation  

BACKGROUND Enteral nutrition should be implemented as early as possible in patients with moderate or severe acute pancreatitis. This study was designed to evaluate the feasibility and Deffectiveness of ultrasound-guided Freka-Trelumina tube placement for enteral nutrition in acute pancreatitis. METHODS Patients with severe acute pancreatitis admitted to Shengjing Hospital of China Medical University who needed Freka-Trelumina tube placement for enteral nutrition and gastrointestinal decompression were included in the current study. The relevant evaluation indicators of tube placement included the success rate of tube placement, tube placement time, tube shift rate, and blocking rate. In addition, the evaluation indicators of ultrasound-guided tube placement (from 1 January 2018 to 31 July 2019) were compared with those of previous endoscope-guided placement (from 1 January 2015 to 31 December 2017) by analysing the data from the electronic medical record system. RESULTS The success rate of ultrasound-guided tube placement was 90.7% (49/54). All 49 patients tolerated the Freka-Trelumina feeding tube. The average ultrasound-guided tube placement time for the 49 patients was 18.4 ± 12.8 min (range, 5-36 min). The Freka-Trelumina feeding tube had a shift rate of 10.2% (5/49). The blocking rate of the Freka-Trelumina feeding tube was 12.2% (6/49). The success rate of tube placement, tube shift rate and blocking rate for endoscope-guided tube placement were 100% (62/62), 11.3% (7/62), and 12.9% (8/62), respectively. The average endoscope-guided tube placement time for the 62 patients was 16.5 ± 5.7 min (range, 12-31 min). The comparison between the ultrasound-guided group and the endoscope-guided group showed that the success rate of tube placement, tube placement time, tube shift rate and blocking rate were similar. CONCLUSION The ultrasound-guided method can be done non-invasively at the bedside, which is safe and convenient, and the Freka-Trelumina feeding tube can be placed in time to achieve the goal of early enteral nutrition and gastrointestinal decompression.
更新日期:2020-01-30
down
wechat
bug