Evaluation of disk halo size after small incision lenticule extraction (SMILE)
Graefe s Archive for Clinical and Experimental Ophthalmology Pub Date : 2019-10-30 , DOI: 10.1007/s00417-019-04481-1
Tian Han 1, 2, 3 , Feng Zhao 1, 2, 3, 4 , Xun Chen 1, 2, 3 , Huamao Miao 1, 2, 3 , Zhuoyi Chen 1, 2, 3 , Xingtao Zhou 1, 2, 3
Affiliation  

Abstract Purpose To investigate changes in objective disk halo size produced by a glare source after small incision lenticule extraction (SMILE) for myopia correction. Methods This prospective clinical study included 45 right eyes of 45 patients with a mean age of 25.40 ± 5.06 years and mean spherical equivalent (SE) of − 6.08 ± 1.90 diopters. Disk halo size was measured with a vision monitor before surgery and at postoperative 1 week and 3 months. Other information was collected, including age, SE, lenticule thickness, lenticule diameter, dark pupil, and pupillary response to light parameters (initial diameter; amplitude, latency, duration, and velocity of contraction; latency, duration, and velocity of dilation; and maximum, minimum, and average pupil size). Results Compared to preoperative values, disk halo size increased significantly at postoperative 1 week (P = 0.026) and returned to baseline at postoperative 3 months (P = 0.349). Preoperative disk halo size significantly correlated with SE (r = − 0.346, P = 0.020), minimum pupil size (r = 0.365, P = 0.014), and average pupil size (r = 0.310, P = 0.038). Disk halo size at postoperative 1 week was significantly correlated with age (r = 0.324, P = 0.030) and minimum pupil size (r = 0.297, P = 0.047). Disk halo size at postoperative 3 months was significantly correlated with lenticule diameter (r = − 0.362, P = 0.015), initial diameter (r = 0.311, P = 0.037), maximum pupil size (r = 0.312, P = 0.037), minimum pupil size (r = 0.440, P = 0.002), and average pupil size (r = 0.373, P = 0.012). Conclusions After SMILE, disk halo size demonstrated a temporary increase and then returned to baseline.

中文翻译:

小切口微透镜提取后圆盘光晕大小的评估(SMILE)

摘要 目的旨在研究用于近视矫正的小切口微透镜提取 (SMILE) 后眩光源产生的物镜圆盘光晕大小的变化。 方法这项前瞻性临床研究包括 45 名患者的 45 只右眼,平均年龄为 25.40 ± 5.06 岁,平均球镜当量 (SE) 为 − 6.08 ± 1.90 屈光度。在手术前、术后 1 周和 3 个月时用视力监测仪测量椎间盘光晕大小。收集其他信息,包括年龄、SE、微透镜厚度、微透镜直径、暗瞳孔和瞳孔对光参数的反应(初始直径;收缩幅度、潜伏期、持续时间和速度;扩张潜伏期、持续时间和速度;以及最大、最小和平均瞳孔大小)。 结果与术前相比,术后 1 周椎间盘光晕大小显着增加(= 0.026)并在术后 3 个月恢复到基线(= 0.349)。术前椎间盘晕大小与 SE 显着相关(r= - 0.346,= 0.020), 最小瞳孔尺寸 (r= 0.365,= 0.014),以及平均瞳孔大小(r= 0.310,= 0.038)。术后1周椎间盘晕大小与年龄显着相关(r= 0.324,= 0.030) 和最小瞳孔尺寸 (r= 0.297,= 0.047)。术后 3 个月的椎间盘光晕大小与微透镜直径显着相关(r= - 0.362,= 0.015), 初始直径 (r= 0.311,= 0.037), 最大瞳孔尺寸 (r= 0.312,= 0.037), 最小瞳孔尺寸 (r= 0.440,= 0.002),以及平均瞳孔大小(r= 0.373,= 0.012)。 结论SMILE 之后,磁盘光环大小出现暂时增加,然后恢复到基线。
更新日期:2019-10-30
down
wechat
bug