The development of wearable devices provides approaches for the realization of self-health care. Easily carried wearable devices allow individual health monitoring at any place whenever necessary. There are various interesting monitoring targets, including body motion, organ pressure, and biomarkers. An efficient use of space in one small device is a promising resolution to increase the functions of wearable devices. Through integration of a microfluidic system into wearable devices, embedding complicated structures in one design becomes possible and can enable multifunction analyses within a limited device volume. This article reviews the reported microfluidic wearable devices, introduces applications to different biofluids, discusses characteristics of the design strategies and sensing principles, and highlights the attractive configurations of each device. This review seeks to provide a detailed summary of recent advanced microfluidic wearable devices. The overview of advanced key components is the basis for the development of future microfluidic wearable devices.

Loading

Article metrics loading...

/content/journals/10.1146/annurev-anchem-091322-082930
2023-06-14
2024-05-02
Loading full text...

Full text loading...

/deliver/fulltext/anchem/16/1/annurev-anchem-091322-082930.html?itemId=/content/journals/10.1146/annurev-anchem-091322-082930&mimeType=html&fmt=ahah

Literature Cited

  1. 1.
    Haghi M, Thurow K, Stoll R. 2017. Wearable devices in medical internet of things: scientific research and commercially available devices. Healthc. Inform. Res. 23:4–15
    [Google Scholar]
  2. 2.
    Takei K, Honda W, Harada S, Arie T, Akita S 2015. Toward flexible and wearable human-interactive health-monitoring devices. Adv. Healthc. Mater. 4:487–500
    [Google Scholar]
  3. 3.
    Wu M, Luo J. 2019. Wearable technology applications in healthcare: a literature review. Online J. Nurs. Inform. 23: https://www.himss.org/resources/wearable-technology-applications-healthcare-literature-review
    [Google Scholar]
  4. 4.
    Iqbal S, Mahgoub I, Du E, Leavitt MA, Asghar W. 2021. Advances in healthcare wearable devices. NPJ Flex. Electron. 5:9
    [Google Scholar]
  5. 5.
    Erdem Ö, Derin E, Shirejini SZ, Sagdic K, Yilmaz EG et al. 2022. Carbon-based nanomaterials and sensing tools for wearable health monitoring devices. Adv. Mater. Technol. 7:2100572
    [Google Scholar]
  6. 6.
    Godfrey A, Hetherington V, Shum H, Bonato P, Lovell N, Stuart S 2018. From A to Z: wearable technology explained. Maturitas 113:40–47
    [Google Scholar]
  7. 7.
    Kireev D, Sel K, Ibrahim B, Kumar N, Akbari A et al. 2022. Continuous cuffless monitoring of arterial blood pressure via graphene bioimpedance tattoos. Nat. Nanotechnol. 17:864–70
    [Google Scholar]
  8. 8.
    Sujith A, Sajja GS, Mahalakshmi V, Nuhmani S, Prasanalakshmi B. 2022. Systematic review of smart health monitoring using deep learning and artificial intelligence. Neurosci. Inform. 2:100028
    [Google Scholar]
  9. 9.
    Promphet N, Ummartyotin S, Ngeontae W, Puthongkham P, Rodthongkum N. 2021. Non-invasive wearable chemical sensors in real-life applications. Anal. Chim. Acta 1179:338643
    [Google Scholar]
  10. 10.
    Abdolmaleki H, Kidmose P, Agarwala S. 2021. Droplet-based techniques for printing of functional inks for flexible physical sensors. Adv. Mater. 33:2006792
    [Google Scholar]
  11. 11.
    Tzianni EI, Hrbac J, Christodoulou DK, Prodromidis MI. 2020. A portable medical diagnostic device utilizing free-standing responsive polymer film-based biosensors and low-cost transducer for point-of-care applications. Sens. Actuators B 304:127356
    [Google Scholar]
  12. 12.
    Shafiee A, Ghadiri E, Kassis J, Williams D, Atala A 2020. Energy band gap investigation of biomaterials: a comprehensive material approach for biocompatibility of medical electronic devices. Micromachines 11:105
    [Google Scholar]
  13. 13.
    Nag A, Mukhopadhyay SC, Kosel J. 2017. Wearable flexible sensors: a review. IEEE Sens. J. 17:3949–60
    [Google Scholar]
  14. 14.
    Pavlov VA, Chavan SS, Tracey KJ. 2020. Bioelectronic medicine: from preclinical studies on the inflammatory reflex to new approaches in disease diagnosis and treatment. Cold Spring Harbor. Perspect. Med. 10:a034140
    [Google Scholar]
  15. 15.
    McGarraugh G, Bergenstal R. 2009. Detection of hypoglycemia with continuous interstitial and traditional blood glucose monitoring using the FreeStyle Navigator Continuous Glucose Monitoring System. Diabetes Technol. Ther. 11:145–50
    [Google Scholar]
  16. 16.
    Zhao M, Leung PS. 2020. Revisiting the use of biological fluids for noninvasive glucose detection. Future Med. Chem. 12:645–47
    [Google Scholar]
  17. 17.
    Lee I, Probst D, Klonoff D, Sode K. 2021. Continuous glucose monitoring systems—current status and future perspectives of the flagship technologies in biosensor research. Biosens. Bioelectron. 181:113054
    [Google Scholar]
  18. 18.
    Martens T, Beck RW, Bailey R, Ruedy KJ, Calhoun P et al. 2021. Effect of continuous glucose monitoring on glycemic control in patients with type 2 diabetes treated with basal insulin: a randomized clinical trial. JAMA 325:2262–72
    [Google Scholar]
  19. 19.
    Bandari N, Dargahi J, Packirisamy M. 2019. Tactile sensors for minimally invasive surgery: a review of the state-of-the-art, applications, and perspectives. IEEE Access 8:7682–708
    [Google Scholar]
  20. 20.
    Lv C, Wang S, Shi C. 2020. A high-precision and miniature fiber Bragg grating-based force sensor for tissue palpation during minimally invasive surgery. Ann. Biomed. Eng. 48:669–81
    [Google Scholar]
  21. 21.
    Chen G, Zheng J, Liu L, Xu L. 2019. Application of microfluidics in wearable devices. Small Methods 3:1900688
    [Google Scholar]
  22. 22.
    Yang Y, Chen Y, Tang H, Zong N, Jiang X. 2020. Microfluidics for biomedical analysis. Small Methods 4:1900451
    [Google Scholar]
  23. 23.
    Lin P-H, Li B-R. 2021. Passively driven microfluidic device with simple operation in the development of nanolitre droplet assay in nucleic acid detection. Sci. Rep. 11:21019
    [Google Scholar]
  24. 24.
    Kilic T, Navaee F, Stradolini F, Renaud P, Carrara S 2018. Organs-on-chip monitoring: sensors and other strategies. Microphysiol. Syst. 2:1–32
    [Google Scholar]
  25. 25.
    Sosa-Hernández JE, Villalba-Rodríguez AM, Romero-Castillo KD, Aguilar-Aguila-Isaías MA, García-Reyes IE et al. 2018. Organs-on-a-chip module: a review from the development and applications perspective. Micromachines 9:536
    [Google Scholar]
  26. 26.
    Kumar A, Parihar A, Panda U, Parihar DS. 2022. Microfluidics-based point-of-care testing (POCT) devices in dealing with waves of COVID-19 pandemic: the emerging solution. ACS Appl. Bio Mater. 5:2046–68
    [Google Scholar]
  27. 27.
    Lee H, Hong YJ, Baik S, Hyeon T, Kim D-H. 2018. Enzyme-based glucose sensor: from invasive to wearable device. Adv. Healthc. Mater. 7:1701150
    [Google Scholar]
  28. 28.
    Madden J, O'Mahony C, Thompson M, O'Riordan A, Galvin P 2020. Biosensing in dermal interstitial fluid using microneedle based electrochemical devices. Sens. Bio-Sens. Res. 29:100348
    [Google Scholar]
  29. 29.
    Samant PP, Prausnitz MR. 2018. Mechanisms of sampling interstitial fluid from skin using a microneedle patch. PNAS 115:4583–88
    [Google Scholar]
  30. 30.
    Tran BQ, Miller PR, Taylor RM, Boyd G, Mach PM et al. 2018. Proteomic characterization of dermal interstitial fluid extracted using a novel microneedle-assisted technique. J. Proteome Res. 17:479–85
    [Google Scholar]
  31. 31.
    Zhang J, Bhattacharyya S, Hickner RC, Light AR, Lambert CJ et al. 2019. Skeletal muscle interstitial fluid metabolomics at rest and associated with an exercise bout: application in rats and humans. Am. J. Physiol. Endocrinol. Metab. 316:E43–53
    [Google Scholar]
  32. 32.
    Thennadil SN, Rennert JL, Wenzel BJ, Hazen KH, Ruchti TL, Block MB. 2001. Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels. Diabetes Technol. Ther. 3:357–65
    [Google Scholar]
  33. 33.
    Kim J, Sempionatto JR, Imani S, Hartel MC, Barfidokht A et al. 2018. Simultaneous monitoring of sweat and interstitial fluid using a single wearable biosensor platform. Adv. Sci. 5:1800880
    [Google Scholar]
  34. 34.
    Isensee K, Müller N, Pucci A, Petrich W. 2018. Towards a quantum cascade laser-based implant for the continuous monitoring of glucose. Analyst 143:6025–36
    [Google Scholar]
  35. 35.
    Ranamukhaarachchi SA, Padeste C, Dübner M, Häfeli UO, Stoeber B, Cadarso VJ. 2016. Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes. Sci. Rep. 6:29075
    [Google Scholar]
  36. 36.
    Jina A, Tierney MJ, Tamada JA, McGill S, Desai S et al. 2014. Design, development, and evaluation of a novel microneedle array-based continuous glucose monitor. J. Diabetes Sci. Technol. 8:483–87
    [Google Scholar]
  37. 37.
    Chang P-H, Weng C-C, Li B-R, Li Y-K. 2020. An antifouling peptide-based biosensor for determination of Streptococcus pneumonia markers in human serum. Biosens. Bioelectron. 151:111969
    [Google Scholar]
  38. 38.
    Lin T-Y, Li B-R, Tsai S-T, Chen C-W, Chen C-H et al. 2013. Improved silicon nanowire field-effect transistors for fast protein–protein interaction screening. Lab Chip 13:676–84
    [Google Scholar]
  39. 39.
    Li B-R, Hsieh Y-J, Chen Y-X, Chung Y-T, Pan C-Y, Chen Y-T. 2013. An ultrasensitive nanowire-transistor biosensor for detecting dopamine release from living PC12 cells under hypoxic stimulation. J. Am. Chem. Soc. 135:16034–37
    [Google Scholar]
  40. 40.
    Chen Y, Lu S, Zhang S, Li Y, Qu Z et al. 2017. Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring. Sci. Adv. 3:e1701629
    [Google Scholar]
  41. 41.
    Bosch JA. 2014. The use of saliva markers in psychobiology: mechanisms and methods. Saliva Secret. Funct. 24:99–108
    [Google Scholar]
  42. 42.
    Lee Y-H, Wong DT. 2009. Saliva: an emerging biofluid for early detection of diseases. Am. J. Dent. 22:241–48
    [Google Scholar]
  43. 43.
    Kaufman E, Lamster IB. 2002. The diagnostic applications of saliva—a review. Crit. Rev. Oral. Biol. Med. 13:197–212
    [Google Scholar]
  44. 44.
    Wang A, Wang CP, Tu M, Wong DTW. 2016. Oral biofluid biomarker research: current status and emerging frontiers. Diagnostics 6:45
    [Google Scholar]
  45. 45.
    Zhang C-Z, Cheng X-Q, Li J-Y, Zhang P, Yi P et al. 2016. Saliva in the diagnosis of diseases. Int. J. Oral Sci. 8:133–37
    [Google Scholar]
  46. 46.
    Arakawa T, Tomoto K, Nitta H, Toma K, Takeuchi S et al. 2020. A wearable cellulose acetate-coated mouthguard biosensor for in vivo salivary glucose measurement. Anal. Chem. 92:12201–7
    [Google Scholar]
  47. 47.
    Lee Y, Howe C, Mishra S, Lee DS, Mahmood M et al. 2018. Wireless, intraoral hybrid electronics for real-time quantification of sodium intake toward hypertension management. PNAS 115:5377–82
    [Google Scholar]
  48. 48.
    García-Carmona L, Martín A, Sempionatto JR, Moreto JR, González MC et al. 2019. Pacifier biosensor: toward noninvasive saliva biomarker monitoring. Anal. Chem. 91:13883–91
    [Google Scholar]
  49. 49.
    Pankratov D, González-Arribas E, Blum Z, Shleev S. 2016. Tear based bioelectronics. Electroanalysis 28:1250–66
    [Google Scholar]
  50. 50.
    Agaoglu S, Diep P, Martini M, Samudhyatha KT, Baday M, Araci IE. 2018. Ultra-sensitive microfluidic wearable strain sensor for intraocular pressure monitoring. Lab Chip 18:3471–83
    [Google Scholar]
  51. 51.
    An H, Chen L, Liu X, Zhao B, Ma D, Wu Z. 2018. A method of manufacturing microfluidic contact lenses by using irreversible bonding and thermoforming. J. Micromech. Microeng. 28:105008
    [Google Scholar]
  52. 52.
    An H, Chen L, Liu X, Zhao B, Zhang H, Wu Z. 2019. Microfluidic contact lenses for unpowered, continuous and non-invasive intraocular pressure monitoring. Sens. Actuators A 295:177–87
    [Google Scholar]
  53. 53.
    Kim J, Kim M, Lee M-S, Kim K, Ji S et al. 2017. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics. Nat. Commun. 8:14997
    [Google Scholar]
  54. 54.
    Yang X, Yao H, Zhao G, Ameer GA, Sun W et al. 2020. Flexible, wearable microfluidic contact lens with capillary networks for tear diagnostics. J. Mater. Sci. 55:9551–61
    [Google Scholar]
  55. 55.
    Moreddu R, Wolffsohn JS, Vigolo D, Yetisen AK. 2020. Laser-inscribed contact lens sensors for the detection of analytes in the tear fluid. Sens. Actuators B 317:128183
    [Google Scholar]
  56. 56.
    Moreddu R, Nasrollahi V, Kassanos P, Dimov S, Vigolo D, Yetisen AK. 2021. Lab-on-a-contact lens platforms fabricated by multi-axis femtosecond laser ablation. Small 17:2102008
    [Google Scholar]
  57. 57.
    Kownacka AE, Vegelyte D, Joosse M, Anton N, Toebes BJ, Lauko J et al. 2018. Clinical evidence for use of a noninvasive biosensor for tear glucose as an alternative to painful finger-prick for diabetes management utilizing a biopolymer coating. Biomacromolecules 19:4504–11
    [Google Scholar]
  58. 58.
    Zhang J, Liu J, Su H, Sun F, Lu Z, Su A 2021. A wearable self-powered biosensor system integrated with diaper for detecting the urine glucose of diabetic patients. Sens. Actuators B 341:130046
    [Google Scholar]
  59. 59.
    Pilardeau P, Vaysse J, Garnier M, Joublin M, Valeri L 1979. Secretion of eccrine sweat glands during exercise. Br. J. Sports Med. 13:118–21
    [Google Scholar]
  60. 60.
    Gamella M, Campuzano S, Manso J, Gonzalez de Rivera G, López-Colino F et al. 2014. A novel non-invasive electrochemical biosensing device for in situ determination of the alcohol content in blood by monitoring ethanol in sweat. Anal. Chim. Acta 806:1–7
    [Google Scholar]
  61. 61.
    Klesges RC, Ward KD, Shelton ML, Applegate WB, Cantler ED et al. 1996. Changes in bone mineral content in male athletes: mechanisms of action and intervention effects. JAMA 276:226–30
    [Google Scholar]
  62. 62.
    Ray TR, Ivanovic M, Curtis PM, Franklin D, Guventurk K et al. 2021. Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management. Sci. Transl. Med. 13:eabd8109
    [Google Scholar]
  63. 63.
    Burns M, Baselt RC. 1995. Monitoring drug use with a sweat patch: an experiment with cocaine. J. Anal. Toxicol. 19:41–48
    [Google Scholar]
  64. 64.
    Koh A, Kang D, Xue Y, Lee S, Pielak RM et al. 2016. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat. Sci. Transl. Med. 8:366ra165
    [Google Scholar]
  65. 65.
    Vinoth R, Nakagawa T, Mathiyarasu J, Mohan AMV. 2021. Fully printed wearable microfluidic devices for high-throughput sweat sampling and multiplexed electrochemical analysis. ACS Sens. 6:1174–86
    [Google Scholar]
  66. 66.
    Boria RA, Olson LE, Goodman SM, Anderson RP. 2014. Spatial filtering to reduce sampling bias can improve the performance of ecological niche models. Ecol. Model. 275:73–77
    [Google Scholar]
  67. 67.
    Xuan X, Pérez-Ràfols C, Chen C, Cuartero M, Crespo GA. 2021. Lactate biosensing for reliable on-body sweat analysis. ACS Sens. 6:2763–71
    [Google Scholar]
  68. 68.
    Nie C, Frijns A, Zevenbergen M, den Toonder J. 2016. An integrated flex-microfluidic-Si chip device towards sweat sensing applications. Sens. Actuators B 227:427–37
    [Google Scholar]
  69. 69.
    Nyein HYY, Bariya M, Tran B, Ahn CH, Brown BJ et al. 2021. A wearable patch for continuous analysis of thermoregulatory sweat at rest. Nat. Commun. 12:1823
    [Google Scholar]
  70. 70.
    Cao Q, Liang B, Tu T, Wei J, Fang L, Ye X. 2019. Three-dimensional paper-based microfluidic electrochemical integrated devices (3D-PMED) for wearable electrochemical glucose detection. RSC Adv. 9:5674–81
    [Google Scholar]
  71. 71.
    Martín A, Kim J, Kurniawan JF, Sempionatto JR, Moreto JR et al. 2017. Epidermal microfluidic electrochemical detection system: enhanced sweat sampling and metabolite detection. ACS Sens. 2:1860–68
    [Google Scholar]
  72. 72.
    Lin H, Tan J, Zhu J, Lin S, Zhao Y et al. 2020. A programmable epidermal microfluidic valving system for wearable biofluid management and contextual biomarker analysis. Nat. Commun. 11:4405
    [Google Scholar]
  73. 73.
    Shay T, Dickey MD, Velev OD. 2017. Hydrogel-enabled osmotic pumping for microfluidics: towards wearable human-device interfaces. Lab Chip 17:710–16
    [Google Scholar]
  74. 74.
    Lin H, Zhao Y, Lin S, Wang B, Yeung C et al. 2019. A rapid and low-cost fabrication and integration scheme to render 3D microfluidic architectures for wearable biofluid sampling, manipulation, and sensing. Lab Chip 19:2844–53
    [Google Scholar]
  75. 75.
    Saha T, Fang J, Mukherjee S, Dickey MD, Velev OD. 2021. Wearable osmotic-capillary patch for prolonged sweat harvesting and sensing. ACS Appl. Mater. Interfaces 13:8071–81
    [Google Scholar]
  76. 76.
    Yokus MA, Saha T, Fang J, Dickey MD, Velev OD, Daniele MA 2019. Towards wearable electrochemical lactate sensing using osmotic-capillary microfluidic pumping Presented at 2019 IEEE SENSORS Montreal, Can.: Oct. 27–30
  77. 77.
    Ma B, Chi J, Xu C, Ni Y, Zhao C, Liu H. 2020. Wearable capillary microfluidics for continuous perspiration sensing. Talanta 212:120786
    [Google Scholar]
  78. 78.
    Lee H-B, Meeseepong M, Trung TQ, Kim B-Y, Lee N-E. 2020. A wearable lab-on-a-patch platform with stretchable nanostructured biosensor for non-invasive immunodetection of biomarker in sweat. Biosens. Bioelectron. 156:112133
    [Google Scholar]
  79. 79.
    Torrente-Rodríguez RM, Tu J, Yang Y, Min J, Wang M et al. 2020. Investigation of cortisol dynamics in human sweat using a graphene-based wireless mHealth system. Matter 2:921–37
    [Google Scholar]
  80. 80.
    Lin P-H, Chang W-L, Sheu S-C, Li B-R. 2020. A noninvasive wearable device for real-time monitoring of secretion sweat pressure by digital display. iScience 23:101658
    [Google Scholar]
  81. 81.
    Zhang S, Zahed MA, Sharifuzzaman M, Yoon S, Hui X et al. 2021. A wearable battery-free wireless and skin-interfaced microfluidics integrated electrochemical sensing patch for on-site biomarkers monitoring in human perspiration. Biosens. Bioelectron. 175:112844
    [Google Scholar]
  82. 82.
    Choi J, Xue Y, Xia W, Ray TR, Reeder JT et al. 2017. Soft, skin-mounted microfluidic systems for measuring secretory fluidic pressures generated at the surface of the skin by eccrine sweat glands. Lab Chip 17:2572–80
    [Google Scholar]
  83. 83.
    Choi J, Kang D, Han S, Kim SB, Rogers JA. 2017. Thin, soft, skin-mounted microfluidic networks with capillary bursting valves for chrono-sampling of sweat. Adv. Healthc. Mater. 6:1601355
    [Google Scholar]
  84. 84.
    Choi J, Bandodkar AJ, Reeder JT, Ray TR, Turnquist A et al. 2019. Soft, skin-integrated multifunctional microfluidic systems for accurate colorimetric analysis of sweat biomarkers and temperature. ACS Sens. 4:379–88
    [Google Scholar]
  85. 85.
    Anastasova S, Crewther B, Bembnowicz P, Curto V, Ip HMD et al. 2017. A wearable multisensing patch for continuous sweat monitoring. Biosens. Bioelectron. 93:139–45
    [Google Scholar]
  86. 86.
    Reeder JT, Choi J, Xue Y, Gutruf P, Hanson J et al. 2019. Waterproof, electronics-enabled, epidermal microfluidic devices for sweat collection, biomarker analysis, and thermography in aquatic settings. Sci. Adv. 5:eaau6356
    [Google Scholar]
  87. 87.
    Xiao J, Liu Y, Su L, Zhao D, Zhao L, Zhang X. 2019. Microfluidic chip-based wearable colorimetric sensor for simple and facile detection of sweat glucose. Anal. Chem. 91:14803–7
    [Google Scholar]
  88. 88.
    Mach AJ, Adeyiga OB, Di Carlo D. 2013. Microfluidic sample preparation for diagnostic cytopathology. Lab Chip 13:1011–26
    [Google Scholar]
  89. 89.
    Zhao J, Guo H, Li J, Bandodkar AJ, Rogers JA. 2019. Body-interfaced chemical sensors for noninvasive monitoring and analysis of biofluids. Trends Chem. 1:559–71
    [Google Scholar]
  90. 90.
    Sotoudegan MS, Mohd O, Ligler FS, Walker GM. 2019. Paper-based passive pumps to generate controllable whole blood flow through microfluidic devices. Lab Chip 19:3787–95
    [Google Scholar]
  91. 91.
    Yang Y, Xing S, Fang Z, Li R, Koo H, Pan T. 2017. Wearable microfluidics: fabric-based digital droplet flowmetry for perspiration analysis. Lab Chip 17:926–35
    [Google Scholar]
  92. 92.
    Ghaffari R, Choi J, Raj MS, Chen S, Lee SP et al. 2020. Soft wearable systems for colorimetric and electrochemical analysis of biofluids. Adv. Funct. Mater. 30:1907269
    [Google Scholar]
  93. 93.
    Benito-Lopez F, Coyle S, Byrne R, Smeaton A, O'Connor NE, Diamond D. 2009. Pump less wearable microfluidic device for real time pH sweat monitoring. Proc. Chem. 1:1103–6
    [Google Scholar]
  94. 94.
    Gao Y, Hou M, Yang R, Zhang L, Xu Z et al. 2019. Highly porous silk fibroin scaffold packed in PEGDA/sucrose microneedles for controllable transdermal drug delivery. Biomacromolecules 20:1334–45
    [Google Scholar]
  95. 95.
    Jiang H, Woodhouse I, Selvamani V, Ma JL, Tang R et al. 2021. A wireless implantable passive intra-abdominal pressure sensing scheme via ultrasonic imaging of a microfluidic device. IEEE Trans. Biomed. Eng. 68:747–58
    [Google Scholar]
/content/journals/10.1146/annurev-anchem-091322-082930
Loading
/content/journals/10.1146/annurev-anchem-091322-082930
Loading

Data & Media loading...

  • Article Type: Review Article
This is a required field
Please enter a valid email address
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error