当前位置:
X-MOL 学术
›
Microchim. Acta
›
论文详情
Our official English website, www.x-mol.net, welcomes your feedback! (Note: you will need to create a separate account there.)
A nanosystem composed of upconversion nanoparticles and N, N-diethyl-p-phenylenediamine for fluorimetric determination of ferric ion
Microchimica Acta ( IF 5.7 ) Pub Date : 2018-07-17 , DOI: 10.1007/s00604-018-2902-7 Min Chen , Felix Y. H. Kutsanedzie , Wu Cheng , Akwasi Akomeah Agyekum , Huanhuan Li , Quansheng Chen
Microchimica Acta ( IF 5.7 ) Pub Date : 2018-07-17 , DOI: 10.1007/s00604-018-2902-7 Min Chen , Felix Y. H. Kutsanedzie , Wu Cheng , Akwasi Akomeah Agyekum , Huanhuan Li , Quansheng Chen
AbstractA system composed of upconversion nanoparticles (UCNPs) and N,N-diethyl-p-phenylenediamine (EPA) is shown to be a useful probe for highly sensitive and selective fluorometric determination of ferric ion. The fluorescence of the UCNPs (under the 980 nm excitation) has peaks at 546, 657, 758 and 812 nm. EPA is readily oxidized by Fe(III) to generate a dye with a peak at 552 nm. This causes an inner filter effect on the fluorescence peaks at 546 nm, whereas the emissions at 657, 758 and 812 nm remained unchanged. Therefore, the iron concentration can be quantified by measurement of the ratio of fluorescence at 546 and 758. Under optimal condition, the ratio drops linearly in the 0.25 to 50 μM. Fe(III) concentration ranges, with a detection limit of 0.25 μM. The method is highly selective and was applied to the analysis of spiked samples (wastewater) where it gave recoveries of between 100.9 and 107.3%; and RSD values between 0.8 and 1.4%. Results are approximately the same as those obtained by AAS. Graphical abstractA method is presented for fluorimetric determination of Fe(III). Fe(III) reacts with N,N-diethyl-p-phenylenediamine (EPA) to generate EPA oxide. The fluorescence peaking at 546 nm is reduced in presence of oxidized EPA via an inner filter.
中文翻译:
由上转换纳米粒子和 N, N-二乙基-对苯二胺组成的纳米系统,用于铁离子的荧光测定
摘要 由上转换纳米粒子 (UCNPs) 和 N,N-二乙基-对苯二胺 (EPA) 组成的系统被证明是一种用于高灵敏度和选择性荧光测定铁离子的有用探针。UCNPs 的荧光(在 980 nm 激发下)在 546、657、758 和 812 nm 处具有峰值。EPA 很容易被 Fe(III) 氧化,生成在 552 nm 处有峰的染料。这会对 546 nm 处的荧光峰产生内部过滤效应,而 657、758 和 812 nm 处的发射保持不变。因此,可以通过测量546和758处的荧光比值来量化铁浓度。在最佳条件下,该比值在0.25至50 μM范围内线性下降。Fe(III) 浓度范围,检测限为 0.25 μM。该方法具有高度选择性,适用于加标样品(废水)的分析,回收率在 100.9% 至 107.3% 之间;RSD 值介于 0.8% 和 1.4% 之间。结果与 AAS 获得的结果大致相同。图形摘要介绍了一种用于 Fe(III) 的荧光测定方法。Fe(III) 与 N,N-二乙基-对苯二胺 (EPA) 反应生成 EPA 氧化物。在 546 nm 处的荧光峰值在氧化 EPA 存在下通过内部过滤器降低。
更新日期:2018-07-17
中文翻译:
由上转换纳米粒子和 N, N-二乙基-对苯二胺组成的纳米系统,用于铁离子的荧光测定
摘要 由上转换纳米粒子 (UCNPs) 和 N,N-二乙基-对苯二胺 (EPA) 组成的系统被证明是一种用于高灵敏度和选择性荧光测定铁离子的有用探针。UCNPs 的荧光(在 980 nm 激发下)在 546、657、758 和 812 nm 处具有峰值。EPA 很容易被 Fe(III) 氧化,生成在 552 nm 处有峰的染料。这会对 546 nm 处的荧光峰产生内部过滤效应,而 657、758 和 812 nm 处的发射保持不变。因此,可以通过测量546和758处的荧光比值来量化铁浓度。在最佳条件下,该比值在0.25至50 μM范围内线性下降。Fe(III) 浓度范围,检测限为 0.25 μM。该方法具有高度选择性,适用于加标样品(废水)的分析,回收率在 100.9% 至 107.3% 之间;RSD 值介于 0.8% 和 1.4% 之间。结果与 AAS 获得的结果大致相同。图形摘要介绍了一种用于 Fe(III) 的荧光测定方法。Fe(III) 与 N,N-二乙基-对苯二胺 (EPA) 反应生成 EPA 氧化物。在 546 nm 处的荧光峰值在氧化 EPA 存在下通过内部过滤器降低。