Reduction of Open-Circuit DC Winding Induced Voltage in Wound Field Switched Flux Machines by Skewing
IEEE Transactions on Industrial Electronics ( IF 7.7 ) Pub Date : 2019-03-01 , DOI: 10.1109/tie.2018.2838106
Z. Z. Wu , Z. Q. Zhu , C. Wang , J. C. Mipo , S. Personnaz , P. Farah

In this paper, the open-circuit dc-winding-induced voltage in a wound field switched flux (WFSFs) machines is analyzed. The phenomenon of open-circuit dc-winding-induced voltage is illustrated and the mechanism is explained. Rotor skewing is proposed to reduce the open-circuit dc-winding-induced voltage, and the optimal skewing angle is analytically derived based on the analytically deduced harmonic orders of the open-circuit dc-winding-induced voltage. Finite-element (FE) analyses show that the open-circuit dc-winding-induced voltages in the analyzed 12-stator-pole partitioned stator WFSF machines having 10-, 11-, 13-, and 14-rotor-pole rotors can be effectively reduced by >94%, while the ac-winding phase-fundamental back-EMFs can be maintained by >95%. Twelve/ten-stator/rotor-pole prototypes with skewed and nonskewed rotors are built and tested to verify the analytical and FE results.

中文翻译:

通过偏斜降低绕线式磁场开关磁通机中开路直流绕组感应电压

在本文中,分析了绕线场开关磁通 (WFSF) 机器中的开路直流绕组感应电压。阐述了开路直流绕组感应电压的现象,并解释了其机理。提出转子偏斜以降低开路直流绕组感应电压,并基于解析推导的开路直流绕组感应电压谐波次数,解析推导出最佳偏斜角。有限元 (FE) 分析表明,所分析的具有 10、11、13 和 14 转子极转子的 12 定子极分区定子 WFSF 电机中的开路直流绕组感应电压可以是有效地降低了 >94%,而交流绕组相基波反电动势可以保持 >95%。